Changes in Electrocardiographic P Wave Parameters after Cryoballoon Ablation and Their Association with Atrial Fibrillation Recurrence.

Clicks: 450
ID: 59207
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #1 of 3 articles by views in annals of noninvasive electrocardiology : the official journal of the international society for holter and noninvasive electrocardiology, inc

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Changes in P wave parameters after circumferential pulmonary vein isolation (CPVI) have been previously identified. In this study, we aimed to determine the changes in P wave parameters surface electrocardiogram (ECG) after cryoballoon ablation (CBA) for atrial fibrillation (AF) and evaluate their relationship with AF recurrence.Sixty-one patients (mean age 53 ± 11 years, 50.8% male) with paroxysmal AF who underwent CBA were enrolled. A surface ECG was obtained from all patients immediately before the procedure, and repeated 12 hours after the procedure. P wave amplitude (Pamp), P wave duration (Pwd), and P wave dispersion (Pdis) values in preprocedural and postprocedural ECGs were measured and compared. Recurrence rates of AF in 3, 6, and 9 months following ablation were recorded for all patients. Changes in P wave parameters were compared between patients with and without AF recurrence.Compared to preprocedural measurements, Pamp (from 0.58 ± 0.18 mV at baseline to 0.48 ± 0.17 mV, P < 0.001), Pwd (from 109.72 ± 18.43 ms at baseline to 91.36 ± 22.53 ms, P < 0.001), and Pdis (from 55.44 ± 20.45 ms at baseline to 45.30 ± 15.31 ms, P < 0.001) were significantly decreased after CBA. The difference in Pamp between pre- and postprocedural values (∆Pamp) was significantly higher in patients without AF recurrence compared to those with recurrence (0.10 ± 0.06 mV vs 0.04 ± 0.01 mV, P = 0.002). There was no difference in Pwd difference (∆Pwd) and Pdis difference (∆Pdis) between patients with and without AF recurrence (P > 0.05).Pamp, Pwd, and Pdis parameters exhibited significant decrease after CBA compared to preprocedural measurements. Decreased Pamp was shown to be a predictor for good clinical outcomes following CBA.
Reference Key
kizilirmak2016changesannals Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal annals of noninvasive electrocardiology : the official journal of the international society for holter and noninvasive electrocardiology, inc
Year 2016
DOI
10.1111/anec.12364
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.