Ultracompliant Carbon Nanotube Direct Bladder Device.

Clicks: 351
ID: 59092
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #5 of 18 articles by views in Advanced healthcare materials

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The bladder, stomach, intestines, heart, and lungs all move dynamically to achieve their purpose. A long-term implantable device that can attach onto an organ, sense its movement, and deliver current to modify the organ function would be useful in many therapeutic applications. The bladder, for example, can suffer from incomplete contractions that result in urinary retention with patients requiring catheterization. Those affected may benefit from a combination of a strain sensor and electrical stimulator to better control bladder emptying. The materials and design of such a device made from thin layer carbon nanotube (CNT) and Ecoflex 00-50 are described and demonstrate its function with in vivo feline bladders. During bench-top characterization, the resistive and capacitive sensors exhibit stability throughout 5000 stretching cycles under physiology conditions. In vivo measurements with piezoresistive devices show a high correlation between sensor resistance and volume. Stimulation driven from platinum-silicone composite electrodes successfully induce bladder contraction. A method for reliable connection and packaging of medical grade wire to the CNT device is also presented. This work is an important step toward the translation of low-durometer elastomers, stretchable CNT percolation, and platinum-silicone composite, which are ideal for large-strain bioelectric applications to sense or modulate dynamic organ states.
Reference Key
yan2019ultracompliantadvanced Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Yan, Dongxiao;Bruns, Tim M;Wu, Yuting;Zimmerman, Lauren L;Stephan, Chris;Cameron, Anne P;Yoon, Euisik;Seymour, John P;
Journal Advanced healthcare materials
Year 2019
DOI
10.1002/adhm.201900477
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.