Efficacy And Safety Of Cryoballoon Ablation For Chinese Patients Over 75 Years Old: A Comparison With A Younger Cohort.

Clicks: 389
ID: 58913
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #3 of 12 articles by views in journal of cardiovascular electrophysiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Cryoballoon ablation (CBA) results in satisfactory outcomes for drug-resistant atrial fibrillation (AF) patients. However, the efficacy and safety of CBA have not yet been tested in the Chinese elderly population. Therefore, this study compared the recurrence of AF and complications of CBA in patients ≥ 75 years and <75 years.A total of 677 patients (<75 years, n=550; ≥75 years, n=127) with paroxysmal (n=603) or persistent (n=74) non-valvular drug-resistant AF were included. The efficacy was assessed by the recurrence of AF, and the safety was evaluated by peri- and post-procedural complications.The CHA2DS2-VASc (2.6±1.7 vs 4.8±1.6, p<0.01) and HAS-BLED (1.8±0.8 vs 2.0±0.8, p=0.01) scores were significantly higher in the elderly group. The instant pulmonary vein isolation (PVI) success rate was comparable (99.11% younger vs 98.98% older, p=0.99). After a mean follow-up time of 12.8±9.6 months, the 1-year freedom from AF rate was 80.6% vs 85.8% in the older and younger groups, respectively, while the survival analysis showed a non-significant difference in the rate of freedom from AF (log-rank P=0.46). Cox regression showed that age was not a predictive factor for AF recurrence and was not dichotomized (hazard ratio (HR)=0.868, 95% confidence interval (CI) 0.509-1.481 p=0.6046) or continuous (HR=0.990, 95% CI 0.968-1.012, p=0.3642). Similar complications rates were observed, including stroke (1.0% younger vs 0.93% older, P=0.95) and major hemorrhagic event (1.2% younger vs 0% elder, P=0.25).The efficacy and safety profiles of CBA in patients older than 75 years are comparable with those in younger patients. This article is protected by copyright. All rights reserved.
Reference Key
zhang2019efficacyjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Zhang, Jun;Ren, Zhongyuan;Wang, Songyun;Zhang, Jingying;Yang, Haotian;Zheng, Yixing;Meng, Weilun;Zhao, Dongdong;Xu, Yawei;
Journal journal of cardiovascular electrophysiology
Year 2019
DOI
10.1111/jce.14220
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.