Measurement of lower limb volume: agreement between the vertically oriented perometer and a tape measure method.
Clicks: 374
ID: 58236
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
67.0
/100
374 views
245 readers
Trending
AI Quality Assessment
Not analyzed
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To investigate the agreement between lower limb volume measurements for the vertically oriented perometer and a tape measure method.Between-methods agreement and test-retest reliability study.University setting.Thirty university staff and students were recruited using convenience sampling with no participant drop-outs.All participants' dominant lower limb volumes were measured using the vertically oriented perometer and a tape measure method.The Bland-Altman difference plot was reported for determining the bias between the two methods and its 95% confidence interval. Test-retest reliability and the measurement error for the perometer method were determined using the ICC(2,1) model and within-subject standard deviation (sw) respectively.There was a lack of agreement between the tape measure and perometer method. The Bland-Altman difference plot showed that the tape measure method overestimated limb volume by 157ml compared to the perometer method. A 95% confidence interval of -834ml to 519ml was observed. The test-retest reliability of the perometer method was ICC(2,1)=0.99. The measurement error of the perometer method was clinically acceptable (sw=121ml).There was a lack of agreement between the two methods investigated. Therefore the perometer and tape measure methods are not interchangeable. It is recommended that future validity and reliability studies for the vertically oriented perometer are conducted on clinical populations.
| Reference Key |
tan2013measurementphysiotherapy
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Tan, Chee-Wee;Coutts, Fiona;Bulley, Cathy; |
| Journal | physiotherapy |
| Year | 2013 |
| DOI |
10.1016/j.physio.2012.12.004
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.