Underdosing of the maxillary sinus for small fields used in newer radiotherapy techniques: Comparison of thermoluminescent dosimeter and Monte Carlo data

Clicks: 290
ID: 57340
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #71 of 148 articles by views in journal of cancer research and therapeutics

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 148 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Aims: To evaluate the underdosing of the maxillary sinus at its distal end produced by air cavity in the path of the 6 MV photon beam. Materials and Methods: A cubic solid water slab phantom of dimensions 18 cm × 18 cm × 18 cm with 4 cm × 4 cm × 4 cm air cavity 3 cm away from its anterior surface was used in this study. The percentage depth dose (PDD) for 6 MV X-rays along the central axis of the cubical air cavity was measured using thermoluminescent dosimeter-100 chips. The EGSnrc/DOSXYZnrc Monte Carlo (MC) code was used to estimate the PDD values in both homogeneous and inhomogeneous conditions. The dose data were generated for 1 cm × 1 cm, 2 cm × 2 cm, 3 cm × 3 cm, and 5 cm × 5 cm field sizes. Results: Average percentage dose reductions at 1 mm beyond the distal surface of the maxillary sinus for the field sizes 1 × 1, 2 × 2, and 3 × 3 cm2 are 42.4%, 39.5%, and 29.4%, respectively. However, for 5 cm × 5 cm field size, there is a dose enhancement (i.e., overdosing) at 1 mm from the distal surface of the maxillary sinus and the average percentage dose enhancement is 5.9%. Also, beyond 1 cm from the air-water interface, there is dose enhancement for all the field sizes. Conclusion: This study showed that the significant dose reduction occurs near the air-water interface for the treatment techniques using small photon fields such as intensity-modulated radiotherapy or other newer techniques. MC-based treatment planning calculation predicts realistic dose distribution while using small photon fields in the treatment of maxillary sinus.
Reference Key
singh2018underdosingjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Singh, Navin;Sharma, Sunil Dutt;Painuly, Nirmal Kumar;Mandal, Abhijit;Agarwal, Lalit Mohan;Sinha, Ashutosh;
Journal journal of cancer research and therapeutics
Year 2018
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.