Evaluation of the photon dose calculation accuracy in radiation therapy of malignant pleural mesothelioma
Clicks: 392
ID: 57335
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
74.0
/100
392 views
314 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #25 of 148 articles by views in journal of cancer research and therapeutics
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 148 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background: Photon dose distribution of malignant pleural mesothelioma (MPM) in matched photon-electron technique is influenced by media inhomogeneity, lateral electronic disequilibrium at interfaces and narrow field. These may influence the dose calculation accuracy, calculated by treatment planning systems (TPS). This study aimed to evaluate the dose calculation accuracy of TiGRT TPS in radiation therapy of MPM.
Materials and Methods: 18 MV photon beams of ONCOR Siemens linear accelerator was simulated using EGSnrc Monte Carlo (MC) code. Data of four patients were used to compare TPS and MC results in different regions included: Open and in-field, under shied and out of field regions.
Results: Compared to MC results, the TPS overestimated the pleura dose coverage (90% of prescribed dose) about 3–12 mm, and also it overestimated the dose in under the shielded regions of lung (4–74%). While the TPS underestimated the dose profile width about 1–16 mm in low dose region (<50% prescribed dose) as well as the out of field region dose (4–100%).
Conclusions: Results showed that TPS underestimated the dose in out of field and overestimated the dose in under the shielded regions. Unlike MC measurements, TPS calculation showed adequate pleural dose coverage. Based on the results, MC calculation can be used in matched photon-electron beam radiation therapy of MPM to modify the TPS photon dose calculations in the presence of heterogeneity, interfaces, and shield in MPM radiotherapy.
| Reference Key |
mahmoudi2018evaluationjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Mahmoudi, Golshan;Farhood, Bagher;Shokrani, Parvaneh;Amouheidari, Alireza;Atarod, Maryam; |
| Journal | journal of cancer research and therapeutics |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.