Dose enhancement in gold nanoparticle-aided radiotherapy for the therapeutic photon beams using Monte Carlo technique
Clicks: 308
ID: 57332
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
67.0
/100
308 views
254 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #64 of 148 articles by views in journal of cancer research and therapeutics
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 148 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background: Gold nanoparticle (GNP)-aided radiation therapy (RT) is useful to make the tumor more sensitive to radiation damage because of the enhancement in the dose inside the tumor region. Polymer gel dosimeter (PGD) can be a good choice for the physical measurement of dose enhancement produced by GNP inside the gel.
Materials and Methods: The present study uses EGSnrc Monte Carlo code to estimate dose enhancement factor (DEF) due to the introduction of GNPs inside the PGD at different concentrations (7 and 18 mg Au/g of gel) when irradiated by therapeutic X-rays of energy 100 kVp, 150 kVp, 6 MV, and 15 MV. The simulation was also carried out to quantify the dose enhancement in PAGAT gel and tumor for 100 kVp X-rays.
Results: For 100 kVp X-rays, average DEF of 1.86 and 2.91 is observed in the PAGAT gel dosimeter with 7 and 18 mg Au/g of gel, respectively. Average DEF of 1.69 and 2.61 is recorded for 150 kVp X-rays with 7 and 18 mg Au/g of gel, respectively. No clinically meaningful DEF was observed for 6 and 15 MV photon beams. Furthermore, the dose enhancement within the PAGAT gel dosimeter and tumor closely matches with each other.
Conclusion: The polymer gel dosimetry can be a suitable method of dose estimation and verification for clinical implementation of GNP-aided RT. GNP-aided RT has the potential of delivering high localized tumoricidal dose with significant sparing of normal structures when the treatment is delivered with low energy X-rays.
| Reference Key |
kakade2015dosejournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Kakade, Nitin Ramesh;Sharma, Sunil Dutt; |
| Journal | journal of cancer research and therapeutics |
| Year | 2015 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.