Radiation interaction parameters for blood samples of breast cancer patients: an MCNP study.
Clicks: 325
ID: 57129
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
79.3
/100
325 views
214 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 3 articles by views in radiation and environmental biophysics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The main goal of this study was to determine radiation interaction parameters such as mass attenuation coefficients, effective atomic numbers, and effective electron densities depending on element concentrations (Na, K, Cu, Zn, Al, Ca, Mg Cr, Fe, Se) in blood samples of patients with breast cancer. Eighty blood samples were collected and analyzed in this study (40 from breast cancer patients and 40 from healthy patients). The determination of element concentrations of the samples was performed with inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-optical emission spectrometry (ICP-OES) after which the element concentrations were normalized to percentage. Mass attenuation coefficients were calculated by Monte Carlo simulation method. In addition, effective atomic numbers and effective electron density values of the blood samples were calculated with the ZXCOM program. One of the most important results of this study is that differences in radiation interaction parameters between the two groups were observed. More specifically, the mass attenuation coefficients of the healthy group's blood samples were higher than those of the cancerous group at photon energies of 50 keV, 100 keV, 250 keV and 500 keV, while they were lower at 1 MeV. All the MCNP results were consistent with the results obtained from ZXCOM. As the main result of this study it is concluded that photon atomic parameters such as mass attenuation coefficient, effective atomic number and electron density may be considered in cancer diagnosis or treatment modalities.
| Reference Key |
toker2019radiationradiation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Toker, Ozan;Caglar, Mustafa;Oz, Ersoy;Bakirdere, Sezgin;Topdagi, Omer;Eyecioglu, Onder;Icelli, Orhan; |
| Journal | radiation and environmental biophysics |
| Year | 2019 |
| DOI |
10.1007/s00411-019-00806-0
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.