Experimental design of switchable solvent-based liquid phase microextraction for the accurate determination of etrimfos from water and food samples at trace levels by GC-MS.
Clicks: 355
ID: 57122
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
78.0
/100
355 views
227 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #42 of 221 articles by views in Environmental monitoring and assessment
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 221 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Presented in this study is a simple but efficient switchable polarity solvent microextraction strategy for etrimfos preconcentration from water and food samples for quantification by gas chromatography mass spectrometry. Repeatability of the extraction process and instrumental measurements were enhanced by using deuterated bisphenol A as internal standard. Significant parameters of the extraction method were fitted into an experimental design model to study the effects of parameters on extraction output, as well as mutual effects of combined parameters. The design model was formed with 51 experimented data obtained from the combination of sodium hydroxide volume, switchable solvent volume, and vortex period at three levels. The method was validated by applying optimum conditions attained from the model predictor. The detection limit was found to be 1.3 ng/mL and it corresponded to an enhancement factor of about 54 folds when compared to direct GC-MS measurement. Etrimfos was not detected in the water and food samples tested but the results (92-107%) obtained from spiked recovery experiments established that etrimfos when present in the selected matrices can be accurately and precisely quantified.
| Reference Key |
firat2019experimentalenvironmental
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Fırat, Merve;Chormey, Dotse Selali;Bakırdere, Sezgin;Turak, Fatma; |
| Journal | Environmental monitoring and assessment |
| Year | 2019 |
| DOI |
10.1007/s10661-019-7797-1
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org