Simultaneous determination of copper and zinc in brass samples by PCR and PLS1 methods using a multiple ion-selective electrode array.
Clicks: 263
ID: 57023
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
69.9
/100
263 views
176 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #120 of 391 articles by views in Talanta
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 391 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A method was developed to determine copper and zinc simultaneously in brass sample using a multiple ion-selective electrode array system and multivariate calibration techniques. The multiple ion-selective electrode array system was consisted of one pH electrode and eight ion selective electrodes which were formed using commercial ionophores and which are mainly sensitive copper and zinc. PCR, PLS1 which are multivariate calibration techniques were used to calibrate the multiple ion-selective electrode array system using five level multivariate calibration design and PCR method was selected as most suitable method. The measurements were performed at pH 10 in ammonia-ammonium chloride buffer. Copper and zinc content of a brass sample were determined by the calibrated multiple ion-selective electrode array system and the composition of brass sample was also determined by gravimetric method. The percentage amount of copper and zinc in brass sample were 64 ± 1 and 26 ± 2, respectively using the gravimetric method. The percentage results obtained in brass samples for copper and zinc were 63 ± 3 and 24 ± 3 by PCR method and 60 ± 5 and 20 ± 7 by PLS1 method, respectively. The obtained results were calculated for a 95% confidence level.
| Reference Key |
eylem2018simultaneoustalanta
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Eylem, Cemil Can;Taştekin, Mustafa;Kenar, Adnan; |
| Journal | Talanta |
| Year | 2018 |
| DOI |
S0039-9140(18)30175-9
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.