Hand-off bundle implementation associated with decreased medical errors and preventable adverse events on an academic family medicine in-patient unit: A pre-post study.

Clicks: 292
ID: 56735
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #92 of 157 articles by views in Medicine

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 157 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
To determine the impact of the implementation of a hand-off bundle on medical errors at an inpatient unit of an academic community teaching hospital. Our secondary objective was to determine the research utility of the use of an all-electronic data collection system for medical errors.A retrospective review was conducted of 1290 admissions 6 months before and after implementation of an improved computerized hand-off tool and training bundle. The study took place at an academic community teaching hospital on a Family Medicine inpatient service caring for patients of all ages. The comparison focused on preventable and non-preventable adverse events.A significant decrease in medical errors was noted. Medical error rate dropped from 6.0 (95% CI, 4.2-8.3) to 2.2 (95% CI, 1.2-3.7) per 100 admissions (P < .001). Preventable medical errors dropped from 0.65 (95% CI, 0.18-1.67) to 0.15 (95% CI, 0.03-0.82) per 100 admissions (P = .194). Non-intercepted potential adverse events dropped from 1.30 (95% CI, 0.56-2.57) to 0.44 (95% CI, 0.09-1.30) per 100 admissions (P = .131). Intercepted potential adverse events dropped from 0.98 (95% CI 0.36-2.13) to 0.74 (95% CI 0.24-1.7) per 100 admissions (P = .766) and errors with little potential for harm dropped from 2.77 (95% CI 1.61-4.43) to 0.74 (95% CI 0.24-1.7) per 100 admissions (P = .009).Implementation of a standardized hand-off bundle was associated with a reduction in medical errors despite a low overall event rate. Further studies are warranted to determine the generalizability of this finding, to examine the overall epidemiology of medical errors and the reporting of such events within general medical teaching units.
Reference Key
dewar2019handoffmedicine Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Dewar, Zachary Ewan;Yurkonis, Theresa;Attia, Maximos;
Journal Medicine
Year 2019
DOI
10.1097/MD.0000000000017459
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.