Auditing local methods for quality assurance in radiotherapy using the same set of predefined treatment plans
Clicks: 460
ID: 56615
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
79.8
/100
460 views
339 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 2 articles by views in physics and imaging in radiation oncology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background and purpose: Local implementation of plan-specific quality assurance (QA) methods for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment plans may vary because of dissimilarities in procedures, equipment and software. The purpose of this work is detecting possible differences between local QA findings and those of an audit, using the same set of treatment plans. Methods: A pre-defined set of clinical plans was devised and imported in the participating institute’s treatment planning system for dose computation. The dose distribution was measured using an ionisation chamber, radiochromic film and an ionisation chamber array. The centres performed their own QA, which was compared to the audit findings. The agreement/disagreement between the audit and the institute QA results were assessed along with the differences between the dose distributions measured by the audit team and computed by the institute. Results: For the majority of the cases the results of the audit were in agreement with the institute QA findings: ionisation chamber: 92%, array: 88%, film: 76% of the total measurements. In only a few of these cases the evaluated measurements failed for both: ionisation chamber: 2%, array: 4%, film: 0% of the total measurements. Conclusion: Using predefined treatment plans, we found that in approximately 80% of the evaluated measurements the results of local QA of IMRT and VMAT plans were in line with the findings of the audit. However, the percentage of agreement/disagreement depended on the characteristics of the measurement equipment used and on the analysis metric. Keywords: Quality assurance, Dosimetry audit, IMRT, VMAT, QA devices
| Reference Key |
seravalli2018auditingphysics
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Seravalli, Enrica;Houweling, Antonetta C.;Battum, Leo Van;Raaben, Thom A.;Kuik, Marc;Pooter, Jacco A. de;Gellekom, Marion P.R. Van;Kaas, Jochem;Vries, Wilfred de;Loeff, Erik A.;Kamer, Jeroen B. Van de; |
| Journal | physics and imaging in radiation oncology |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
chemistry
Medicine (General)
Medicine
Engineering (General). Civil engineering (General)
Technology
Diseases of the circulatory (Cardiovascular) system
physics
medical physics. medical radiology. nuclear medicine
neoplasms. tumors. oncology. including cancer and carcinogens
ophthalmology
applied optics. photonics
|
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.