A Novel Technique for Selecting EMG-Contaminated EEG Channels in Self-Paced Brain-Computer Interface Task Onset.
Clicks: 397
ID: 56014
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
70.0
/100
397 views
255 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #2 of 10 articles by views in ieee transactions on neural systems and rehabilitation engineering : a publication of the ieee engineering in medicine and biology society
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Electromyography artifacts are a well-known problem in electroencephalography studies [brain-computer interfaces (BCIs), brain mapping, and clinical areas]. Blind source separation (BSS) techniques are commonly used to handle artifacts. However, these may remove not only the EMG artifacts but also some useful electroencephalography (EEG) sources. To reduce this useful information loss, we propose a new technique for statistically selecting EEG channels that are contaminated with class-dependent EMG (henceforth called EMG-CCh). The EMG-CCh is selected based on the correlation between EEG and facial EMG channels. They were compared (using a Wilcoxon test) to determine whether the artifacts played a significant role in class separation. To ensure that the promising results are not due to the weak EMG removal, reliability tests were done In our data set, the comparison results between BSS artifact removal applied in two ways, to all channels and only to EMG-CCh showed that ICA, PCA, and BSS-CCA can yield significantly better ( ) class separation with the proposed method (79% of the cases for ICA, 53% for PCA, and 11% for BSS-CCA). With BCI competition data, we saw improvement in 60% of the cases for ICA and BSS-CCA. The simple method proposed in this paper showed improvement in class separation with both our data and the BCI competition data. There are no existing methods for removing EMG artifacts based on the correlation between the EEG and EMG channels. Also, the EMG-CCh selection can be used on its own or it can be combined with pre-existing artifact handling methods. For these reasons, we believe that this method can be useful for other EEG studies.
| Reference Key |
song2018aieee
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Song, YoungJae;Sepulveda, Francisco; |
| Journal | ieee transactions on neural systems and rehabilitation engineering : a publication of the ieee engineering in medicine and biology society |
| Year | 2018 |
| DOI |
10.1109/TNSRE.2018.2847316
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.