Removing muscle artifacts from EEG data of people with cognitive impairment using high order statistic methods.

Clicks: 347
ID: 56006
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #4 of 5 articles by views in Hellenic journal of nuclear medicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Often, people with Subjective Cognitive Impairment (SCI), Mild Cognitive Impairment (MCI) and dementia are underwent to Electroencephalography (EEG) in order to evaluate through biological indexes the functional connectivity between brain regions and activation areas during cognitive performance. EEG recordings are frequently contaminated by muscle artifacts, which obscure and complicate their interpretation. These muscle artifacts are particularly difficult to be removed from the EEG in order the latter to be used for further clinical evaluation. In this paper, we proposed a new approach in removing muscle artifacts from EEG data using a method that combines second and high order statistical information.In the proposed system the muscle artifacts of the EEG signal are removed by using the Independent Vector Analysis (IVA). The latter was formulated as a general joint Blind Source Separation (BSS) method that uses both second-order and higher order statistical information and thus takes advantage of both Independent Component Analysis (ICA) and Canonical Correlation Analysis (CCA). Diagonalization methods for IVA in the proposed system were reworked based on SCHUR decomposition offering a faster second order blind identification algorithm that can be used on time demanding applications.The proposed method is evaluated in both simulated and real EEG data. To quantitatively examine the performance of the new method, two objective measures were adopted. The first measure is the Root Mean Square Error (RMSE) while the second is the Signal-to-noise-ratio (SNR).The proposed method overcomes with the need of removing muscle artifacts on both realistic simulated EEG data and brain activity from people with cognitive impairment.
Reference Key
kalogiannisremovinghellenic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kalogiannis, Grigorios;Chassapis, George;Tsolaki, Magda;
Journal Hellenic journal of nuclear medicine
Year Year not found
DOI
DOI not found
URL URL not found
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.