Short circuiting in a denitrifying activated sludge tank.

Clicks: 182
ID: 54776
2005
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #54 of 69 articles by views in water science and technology : a journal of the international association on water pollution research

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The presence of a short circuit flow in a denitrifying activated sludge tank was identified and modelled. Tracer tests with pulse addition of lithium salt were used to investigate the hydraulics of the tank. The lithium concentration in the effluent was detected and residence time distribution (RTD) curves were generated. Hydraulic models based on completely stirred tank reactors (CSTRs) in series were generated from the RTD curves and the models were compared. The short circuit problem was successfully described using the Martin model, where the inflow is divided into two strands. Each strand was modelled as a number of CSTRs in series. At a normal flow the results of the model show that the tank has 12.8% dead volume, 85.8% main volume and 1.3% short circuiting volume. The inflow was divided into 91.9% entering the main volume and 8.1% entering the short circuiting volume. The mean velocity of the short circuiting stream was estimated to 0.4 m/s. At maximum flow the short circuiting stream was even larger and handled 24.3% of the flow. The short circuiting stream was identified in the upper part of the tank due to the position of the inlet and the outlet. The configuration of a tank including the use of baffles, the geometry of the inlet and mixer configuration should be considered carefully if short circuiting is to be avoided.
Reference Key
kjellstrand2005shortwater Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kjellstrand, R;Mattsson, A;Niklasson, C;Taherzadeh, M J;
Journal water science and technology : a journal of the international association on water pollution research
Year 2005
DOI
DOI not found
URL URL not found
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.