Electrochemically Reduced Graphene Oxide-nafion/Au Nanoparticle Modified Electrode for Hydrogen Peroxide Sensing
Clicks: 501
ID: 54400
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
66.2
/100
501 views
357 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 3 articles by views in nanomaterials and nanotechnology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
n this paper, a non-enzymatic hydrogen peroxide (H2O2) sensor, based on Au nanoparticles (AuNPs) electrodepos‐ ited on an electrochemically reduced graphene oxide(ER‐ GO)-Nafion modified glass carbon electrode (GCE), was reported. The graphene oxide-(GO-)Nafion nanocompo‐ sites were first assembled on the GCE surface to produce a GO-Nafion electrode. GO was then electrochemically reduced to produce an ERGO-Nafion modified GCE (to be subsequently denoted as GCE/ERGO-Nafion). Afterwards, AuNPs were electrodeposited on the modified GCE to form a GCE/ERGO-Nafion/AuNPs electrode. The ERGO-Nafion nanocomposites and the electrodeposited AuNPs were characterized by infrared spectroscopy and scanning electron microscopy (SEM). The results showed that the GO was reduced successfully and the AuNPs were uniformly dispersed on the GCE/ERGO-Nafion electrode with a size of about 48nm. The cyclic voltammograms and the am‐ perometric method were used to evaluate the electrocata‐ lytic properties of the GCE/ERGO-Nafion/AuNPs electrode. The results showed that the modified electrode displayed good electrocatalytic activity in relation to the reduction of H2O2 with a detection limit of 2 μM of (H2O2) based on a signal-to-noise ratio of three. The sensor also indicated great sensitivity (574.8 μA/(mM cm2)), wide
linear range (0.02-23 mM), good selectivity and reproduci‐ bility, and long-term stability.
| Reference Key |
lv2016electrochemicallynanomaterials
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Lv, Yajie;Wang, Fang;Zhu, Hui;Zou, Xiaorong;Tao, Cheng-an;Wang, Jianfang; |
| Journal | nanomaterials and nanotechnology |
| Year | 2016 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.