Label-free and highly selective electrochemical aptasensor for detection of PCBs based on nickel hexacyanoferrate nanoparticles/reduced graphene oxides hybrids.

Clicks: 332
ID: 54357
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #26 of 85 articles by views in Biosensors & bioelectronics

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In consideration of the urgent need to determine polychlorinated biphenyls (PCBs) in the environment, a label-free and highly selective electrochemical aptasensor was constructed for determining PCBs based on nickel hexacyanoferrate nanoparticles (NiHCF NPs)/reduced graphene oxides (rGO) hybrids. NiHCF NPs/rGO hybrids with small size of about 5 nm NiHCF NPs were synthesized for the first time by in situ co-deposition of NiHCF NPs on rGO surface. In the hybrids, rGO with large area and good conductivity can supply more space for loading NiHCF NPs and improve the conductivity of the hybrids. NiHCF NPs that can be used to be act as a signal probe exhibit a couple of well-defined peaks with highly reversible redox ability and good stability. Here, PCB77 as a model molecule, the anti-PCB77 aptamer was anchored on the NiHCF NPs/rGO hybrids by covalent bonding reaction. The design aptasensor for detecting PCB77 exhibits a favorable linear response from 1.0 to 100.0 ng/L with a low detection limit of 0.22 ng/L. Meanwhile, it displays good selectivity for PCB77 detection due to the specificity and high affinity of aptamer to PCB77. Additionally, the application of the aptasensor was evaluated in real environmental samples.
Reference Key
fan2019labelfreebiosensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Fan, Lifang;Wang, Guizhen;Liang, Wenting;Yan, Wenjun;Guo, Yujing;Shuang, Shaomin;Dong, Chuan;Bi, Yingpu;
Journal Biosensors & bioelectronics
Year 2019
DOI
S0956-5663(19)30807-3
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.