Splintless surgery using patient-specific osteosynthesis in Le Fort I osteotomies: a randomized controlled multi-centre trial.

Clicks: 334
ID: 53538
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1 of 6 articles by views in international journal of oral and maxillofacial surgery

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The accuracy of orthognathic surgery has improved with three-dimensional virtual planning. The translation of the planning to the surgical result is reported to vary by >2mm. The aim of this randomized controlled multi-centre trial was to determine whether the use of splintless patient-specific osteosynthesis can improve the accuracy of maxillary translation. Patients requiring a Le Fort I osteotomy were included in the trial. The intervention group was treated using patient-specific osteosynthesis and the control group with conventional osteosynthesis and splint-based positioning. Fifty-eight patients completed the study protocol, 27 in the patient-specific osteosynthesis group and 31 in the control group. The per protocol median anteroposterior deviation was found to be 1.05mm (interquartile range (IQR) 0.45-2.72mm) in the patient-specific osteosynthesis group and 1.74mm (IQR 1.02-3.02mm) in the control group. The cranial-caudal deviation was 0.87mm (IQR 0.49-1.44mm) and 0.98mm (IQR 0.28-2.10mm), respectively, whereas the left-right translation deviation was 0.46mm (IQR 0.19-0.96mm) in the patient-specific osteosynthesis group and 1.07mm (IQR 0.62-1.55mm) in the control group. The splintless patient-specific osteosynthesis method improves the accuracy of maxillary translations in orthognathic surgery and is clinically relevant for planned anteroposterior translations of more than 3.70mm.
Reference Key
kraeima2019splintlessinternational Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kraeima, J;Schepers, R H;Spijkervet, F K L;Maal, T J J;Baan, F;Witjes, M J H;Jansma, J;
Journal international journal of oral and maxillofacial surgery
Year 2019
DOI
S0901-5027(19)31272-X
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.