Six artificial recharge pilot replicates to gain insight into water quality enhancement processes.

Clicks: 345
ID: 53369
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #72 of 409 articles by views in Chemosphere

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 409 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The processes that control water quality improvement during artificial recharge (filtering, degradation, and adsorption) can be enhanced by adding a reactive barrier containing different types of sorption sites and promoting diverse redox states along the flow path, which increases the range of pollutants degraded. While this option looks attractive for renaturazing reclaimed water, three issues have to be analyzed prior to broad scale application: (1) a fair comparison between the system with and without reactive barrier; (2) the role of plants in prevention of clogging and addition of organic carbon; and (3) the removal of pathogens. Here, we describe a pilot installation built to address these issues within a waste water treatment plant that feeds on water reclaimed from the secondary outflow. The installation consists of six systems of recharge basin and aquifer with some variations in the design of the reactive barrier and the heterogeneity of the aquifer. We report preliminary results after one year of operation. We find that (1) the systems are efficient in obtaining a broad range of redox conditions (at least iron and manganese reducing), (2) contaminants of emerging concern are significantly removed (around 80% removal, but very sensitive to the compound), (3) pathogen indicators (E. coli and Enterococci) drop by some 3-5 log units, and (4) the recharge systems maintained infiltration capacity after one year of operation (only the system without plants and the one without reactive barrier displayed some clogging). Overall, the reactive barrier enhances somewhat the performance of the system, but the gain is not dramatic, which suggests that barrier composition needs to be improved.
Reference Key
valhondo2019sixchemosphere Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Valhondo, Cristina;Martínez-Landa, Lurdes;Carrera, Jesús;Díaz-Cruz, Silvia M;Amalfitano, Stefano;Levantesi, Caterina;
Journal Chemosphere
Year 2019
DOI
S0045-6535(19)32065-X
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.