Recomendações para se evitar grandes erros de dose em tratamentos radioterapêuticos Recommendations to avoid gross errors of dose in radiotherapeutic treatments
Article Quality & Performance Metrics
Readership in this journal
PopularRanked #2 of 4 articles by views in radiologia brasileira
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
Human mistakes are an important source of errors in radiotherapy and may occur at every step of the radiotherapeutic planning and treatment. To reduce this level of uncertainties, several specialized organizations have recommended a comprehensive quality assurance program. In Brazil, the requirement for these programs has been strongly stressed, and most radiotherapy services have pursued this goal regarding radiation units and dosimetry equipment, as well as the verification of the calculations of the patient's dose and the revision of the plan charts. As a contribution to the improvement of quality control, we present some recommendations to avoid failure of treatment due to error in the delivered dose, such as redundant check of the manual or computer calculations, weekly check of the total dose for each patient, and prevention of inadvertent access to any safety system of the equipment by any staff member that is only supposed to operate the machine. Moreover, the use of a computerized treatment record and verification system should be considered in order to eliminate errors due to incorrect selection of the treatment parameters, in a daily basis. We report four radioactive incidents with patient injuries occurred throughout the world and some gross errors of dose.
| Reference Key |
souza2001recomendacesradiologia
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Souza, Cleber Nogueira de;Monti, Carlos Roberto;Sibata, Cláudio Hissao; |
| Journal | radiologia brasileira |
| Year | 2001 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.