SAVIOR ICU: sonification and vibrotactile interface for the operating room and intensive care unit.
Clicks: 384
ID: 53326
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
72.7
/100
384 views
260 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 7 articles by views in Journal of clinical monitoring and computing
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Alarm fatigue is an issue for healthcare providers in the intensive care unit, and may result from desensitization of overbearing and under-informing alarms. To directly increase the overall identification of medical alarms and potentially contribute to a downstream decrease in the prevalence of alarm fatigue, we propose advancing alarm sonification by combining auditory and tactile stimuli to create a multisensory alarm. Participants completed four trials-two multisensory (auditory and tactile) and two unisensory (auditory). Analysis compared the unisensory trials to the multisensory trials based on the percentage of correctly identified point of change, direction of change and identity of three physiological parameters (indicated by different instruments): heart rate (drums), blood pressure (piano), blood oxygenation (guitar). A repeated-measures of ANOVA yielded a significant improvement in performance for the multisensory group compared to the unisensory group (p < 0.05). Specifically, the multisensory group had better performance in correctly identifying parameter (p < 0.05) and point of change (p < 0.05) compared to the unisensory group. Participants demonstrated a higher accuracy of identification with the use of multisensory alarms. Therefore, multisensory alarms may relieve the auditory burden of the medical environment and increase the overall quality of care and patient safety.
| Reference Key |
burdick2019saviorjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Burdick, Kendall J;Jorgensen, Seiver K;Combs, Taylor N;Holmberg, Megan O;Kultgen, Samantha P;Schlesinger, Joseph J; |
| Journal | Journal of clinical monitoring and computing |
| Year | 2019 |
| DOI |
10.1007/s10877-019-00381-1
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.