Simultaneous Quantification of Seven Constituents from Zaoren Anshen Prescription and Four Endogenic Components in Rat Plasma by UHPLC-TSQ-MS/MS and the Application of the Correlation Study.

Clicks: 401
ID: 53297
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #4 of 9 articles by views in Chemical & pharmaceutical bulletin

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A highly rapid and sensitive ultra-performance liquid chromatography-tandem triple quadrupole mass spectrometry (UHPLC-TSQ-MS/MS) method was developed for the simultaneous determination of 7 constituents from Zaoren Anshen prescription (ZAP) and 4 endogenic components in rat plasma. The proteins in the plasma samples were removed using acetonitrile. The separation of the 11 components was performed on an Alltima C18 column (150 × 4.6 mm, 5 µm) with acetonitrile and 0.01% formic acid water as the mobile phase. Quantification of the 11 components was performed by multiple reaction monitoring (MRM), and the electrospray ion source polarity was switched between positive and negative modes. The method exhibited good linearity for the 11 components (R > 0.9942). The lower quantitative limit for the 11 components was in the range from 0.90-9.95 ng/mL. The precision was evaluated by intraday and interday assays, with all relative standard deviation (RSD)% values within 14.92%. The relative error of the accuracy ranged from -9.90 to 14.93%. The recovery ranged from 73.94 to 101.06%, and the matrix effects of the 7 components ranged from 80.06 to 105.70%. The developed method was successfully applied for correlation analysis for the simultaneous quantification of the 7 constituents from ZAP and 4 endogenic components in rat plasma after ZAP treatment.
Reference Key
li2019simultaneouschemical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Li, Rong;Wang, Lin;Wang, Xiao;Zhang, Dian;Zhang, Yafeng;Li, Zhuo;Fang, Minfeng;
Journal Chemical & pharmaceutical bulletin
Year 2019
DOI
10.1248/cpb.c19-00299
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org