Biometry of myopia in college students: IOL-Master study
Clicks: 460
ID: 53048
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
72.8
/100
460 views
323 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #6 of 48 articles by views in guoji yanke zazhi
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
AIM: To measure axial length(AL), horizontal and vertical corneal refractive power(K1, K2), anterior chamber depth(ACD)and corneal diameter(white to white)of myopia in college students by IOL-Master(Zeiss Humphrey Systems)and detect the correlation between diopter and all above refractive components. METHODS: The IOL-Master was used in the measurement of the AL, K1, K2, ACD and corneal diameter(white to white)in 1 059 college students(2 118 eyes)with myopia, and AL/CR was calculated. Their diopter was measured by computer refractor. They were divided into three groups according to different mean spherical equivalent diopters: group A of low myopia: < -3.00D(738 eyes), group B of middle myopia: -3.00--6.00D(989 eyes), C group of high myopia: >-6.00D(391 eyes). The SPSS 18.0 was used for the statistical analysis. RESULTS: With the increase of diopter, the AL in myopia eyes was increased and the AL increased significantly in each myopia group(P<0.01); There were statistically significant differences for AL classified with refractive error(P<0.01). There was no significant difference between group A and group B in K1(P>0.05)and there were significant differences among three groups in K2(P<0.05), but there was only significant correlation between K1, K2 and refractive error in middle myopia(P<0.05). The AL was negatively correlated with K1 and K2 in three groups(P<0.01). There was no significant differences between group B and group C in ACD(P>0.05), but there was only significant correlation between ACD and refractive error in low myopia(P<0.01). There was no significant differences of corneal diameter among three groups(P>0.05)and also there was no significant correlation between corneal diameter and refractive error in three groups(P>0.05). AL/CR was 3.183±0.132, the AL/CR ratio was negatively correlated with diopter of myopia(r=-0.761,P=0.000). CONCLUSION: The development of axial length is the main reason in myopia of college students. Middle myopia is induced by both axial length and refractive power. ACD has little effects on diopter of myopia, but corneal diameter has no effects on diopter of myopia.
| Reference Key |
du2013biometryguoji
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Du, Yuan-Yuan;Zhang, Wen-Fang;Lü, Peng;Ren, WanNa;Li, Yu-Ting;Wang, Wan-Peng;Zhou, Ran; |
| Journal | guoji yanke zazhi |
| Year | 2013 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org