Poly(N-acryloyl-glucosamine-co-methylenebisacrylamide)-based hydrophilic magnetic nanoparticles for the extraction of aminoglycosides in meat samples.

Clicks: 344
ID: 52347
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #15 of 58 articles by views in journal of chromatography a

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Poly(N-acryloyl-glucosamine-co-methylenebisacrylamide) (poly(AGA-co-MBA))-modified FeO nanoparticles were prepared via simple aqueous surface polymerization. The resultant FeO@poly(AGA-co-MBA) nanoparticles were used as hydrophilic magnetic solid phase extraction sorbents. Ten aminoglycosides were selected as model analytes to evaluate the extraction performance and mechanism of the sorbents. The prepared magnetic nanoparticles were characterized by Fourier transformed infrared spectroscopy, elemental analysis, a vibrating sample magnetometer, and so on. The sorbents exhibited efficient extraction towards model analytes in hydrophilic interaction chromatography. Only 10.0 mg of sorbent was needed to adsorb analytes from 10.0 mL of a sample solution within a short time (5.0 min). Under optimized conditions, FeO@poly(AGA-co-MBA) nanoparticles were applied in the sample preparation for the analysis of 10 aminoglycosides in meat samples by high-performance liquid chromatography-tandem mass spectrometry. The limits of detection (LODs) for the 10 aminoglycosides were in the range of 0.6-23.6 µg kg. Satisfactory recoveries of spiked meat samples from 84.6-98.3% with acceptable relative standard deviations from 3.1% to 7.8% were achieved. Compared to other reported methods for the analysis of aminoglycosides, the present work had comparable or higher sensitivities with a simple extraction procedure. The proposed hydrophilic interaction extraction sorbents are promising as powerful alternatives for extracting and enriching aminoglycosides in animal-derived food samples.
Reference Key
liu2019polynacryloylglucosaminecomethylenebisacrylamidebasedjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Liu, Huiying;Li, Nan;Liu, Xuebo;Qian, Yongzhong;Qiu, Jing;Wang, Xiaoning;
Journal journal of chromatography a
Year 2019
DOI
S0021-9673(19)30901-X
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.