Chip-scale high Q-factor glassblown microspherical shells for magnetic sensing.
Clicks: 462
ID: 51498
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
462 views
41 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #8 of 262 articles by views in aip advances
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 262 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A whispering gallery mode resonator based magnetometer using chip-scale glass microspherical shells is described. A neodynium micro-magnet is elastically coupled and integrated on top of the microspherical shell structure that enables transduction of the magnetic force experienced by the magnet in external magnetic fields into an optical resonance frequency shift. High quality factor optical microspherical shell resonators with ultra-smooth surfaces have been successfully fabricated and integrated with magnets to achieve Q-factors of greater than 1.1 × 10 and have shown a resonance shift of 1.43 GHz/mT (or 4.0 pm/mT) at 760 nm wavelength. The main mode of action is mechanical deformation of the microbubble with a minor contribution from the photoelastic effect. An experimental limit of detection of 60 nT Hz at 100 Hz is demonstrated. A theoretical thermorefractive limited detection limit of 52 pT Hz at 100 Hz is calculated from the experimentally derived sensitivity. The paper describes the mode of action, sensitivity and limit of detection is evaluated for the chip-scale whispering gallery mode magnetometer.
| Reference Key |
freeman2018chipscaleaip
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Freeman, Eugene;Wang, Cheng-Yu;Sumaria, Vedant;Schiff, Steven J;Liu, Zhiwen;Tadigadapa, Srinivas; |
| Journal | aip advances |
| Year | 2018 |
| DOI |
10.1063/1.5030460
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.