Interpretation of in-air output ratio of wedged fields in different measurement conditions
Clicks: 350
ID: 51351
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
70.5
/100
350 views
230 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #2 of 6 articles by views in journal of medical signals and sensors
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background: The collimator scatter factor (Sc) is one of the most important parameters in monitor unit (MU) calculation. There are several factors that impact Scvalues, including head structures, backscatter in dose monitoring chambers, and wedges. The objective of this study was to investigate the variation of Scwith different buildup cap materials, wall thickness of buildup caps, source-to-chamber distances (SCDs), ionization chambers, and wedge angles in 6 MV photon beam. Methods: In this study, copper and Perspex buildup caps were made with two different thicknesses for each buildup cap. Measurements were performed on an Elekta Compact medical linear accelerator (6 MV) using RK dosimeter with a sensitive volume of 0.120 cm3 and Farmer-type ion chamber with a sensitive volume of 0.65 cm3. In all measurements, buildup caps and ionization chambers were positioned such as to stand vertically to the beam central axis. It was also investigated the effect of internal wedge with different angles (30° and 60°) different SCDs on Sc. Results: It was found in large field sizes, Scvalues in Perspex buildup cap were higher than copper. Different SCDs and type of ion chamber and wall thickness of buildup caps had no significant influence on Scvalues. The presence of wedge influenced Scvalues significantly. Variation of Scin wedged fields compared to open fields had a maximum deviation of 0.9% and 6.8% in 30° and 60° wedge angles, respectively. Conclusion: It was found that the presence of wedges had a significant influence on Scand increases with wedge angles. As such, it should be taken into account in manual MU calculations.
| Reference Key |
mehnati2019interpretationjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Mehnati, Parinaz;Biglari, Farideh;Jomehzadeh, Ali; |
| Journal | journal of medical signals and sensors |
| Year | 2019 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.