Comparing dose rates near a radioactive patient evaluated using various source models: point, line, cylinder, and anthropomorphic phantoms.
Clicks: 318
ID: 51324
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
68.0
/100
318 views
203 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #5 of 18 articles by views in health physics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This study investigated radiation exposures from nuclear medicine patients by systematically comparing the dose rates calculated using various source models, ranging from simplified point, line, and cylinder sources to high-quality anthropomorphic phantoms. Three widely used radionuclides, (99m)Tc, (18)F, and I(131), were considered in these source models with uniform or organ-dependent distributions. Conducting Monte Carlo simulations with anthropomorphic phantoms is a realistic but time-consuming approach. The point source model is simple but too conservative, overestimating dose rates by approximately a factor of 2 at a distance of 30 cm and by 30-40% at 1 m. Both the line and cylinder source models provided improved estimates, reducing the overestimation of dose rates to 10-20% at distances of interest. The line source model was comparable to the cylinder source model because of the offset of two competing effects (i.e., attenuation and buildup) caused by the source volume. The influence of various photon energies and cylinder sizes on the result of compensating errors was examined to evaluate the effective range of the line source model. The line source model, which is relatively easy to implement and predicts slightly conservative dose rates, is considered the most practical method for calculating dose rates near radioactive patients. An application of the line source model to 51 post-thyroidectomy patients in Taiwan was demonstrated. The consistency between calculations and measurements was satisfactory after considering the room-scattering effect.
| Reference Key |
liu2015comparinghealth
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Liu, Yi-Ching;Lee, Kuo-Wei;Sheu, Rong-Jiun; |
| Journal | health physics |
| Year | 2015 |
| DOI |
10.1097/HP.0000000000000294
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.