Unprecedented reversible real-time luminescent sensing of HS in the gas phase.

Clicks: 392
ID: 512
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #12 of 194 articles by views in Analytical chemistry

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 194 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Hydrogen sulfide monitoring has become essential in the natural gas industry, biogas production, waste water treatment plants, paper mills, sewers and landfills of waste due to its toxic, irritating, extremely flammable and corrosive features. However, each of the current monitoring technologies (gas chromatography, lead acetate tape, electrochemical, UV and NIR absorption) has its own limitations. Furthermore, the existing luminescent molecular probes for HS cannot monitor it continuously due to the irreversibility of their reaction with the analyte. Herein, we report the development and application of the first reversible HS luminescent sensor. The sensing layer capitalizes on the highly photooxidizing phosphorescent [bis(1,10-phenanthroline) (1,4,5,8-tetraazaphenanthrene)]ruthenium(II) dication immobilized on alkali-treated silica microspheres, interrogated with a dedicated fiberoptic phase-sensitive luminometer. The chemosensing mechanism is a fully reversible electron transfer from the analyte to the photoexcited dye. The HS optosensor exhibits a 0.34 to 50 ppmv dynamic range, a limit of detection equal to 0.025 ppmv, repeat-ability and reproducibility better than 3.2%, plus response and recovery times (t and t) shorter than 240 s. The HS luminescent sensor performance has been verified for more than 6 months in a biomethane production plant, showing an excellent stability with automatic daily maintenance.
Reference Key
urriza-arsuaga2018unprecedented Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Urriza-Arsuaga, Idoia;Bedoya, Maximino;Orellana, Guillermo;
Journal Analytical chemistry
Year 2018