Active control of noise in a duct using the sparsely coded time-domain underdetermined multichannel inverse filters.
Clicks: 271
ID: 50426
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
63.8
/100
271 views
184 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #16 of 37 articles by views in the journal of the acoustical society of america
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A time-domain underdetermined multichannel inverse filtering (TUMIF) technique is proposed for active feedforward control of noise in ducts. Traditionally, feedforward active control is formulated as an overdetermined inverse filtering problem which generally leads to non-zero residual noise. In this work, a multichannel control approach is presented from the perspectives of vector subspaces and model-matching framework. By introducing multiple secondary sources, the problem can be reformulated into an underdetermined system, which admits infinite number of exact solutions with zero residual noise. However, the finite impulse response filter obtained using the least-square method tends to be prohibitively long for real-time implementation. To tackle this problem, two sparse coding techniques, the least absolute shrinkage and selection operator algorithm and the orthogonal matching pursuit algorithm, are exploited to reduce the controller orders. Simulation and experiment results obtained using a digital signal processor demonstrated that a two-channel reduced-order TUMIF controller has achieved significantly higher noise reduction than the filtered-x least-mean-squares algorithm.
| Reference Key |
bai2019activethe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Bai, Mingsian R;Chen, Hung-Yu;Yang, Lihao;Huang, Shin-Cheng; |
| Journal | the journal of the acoustical society of america |
| Year | 2019 |
| DOI |
10.1121/1.5123465
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.