Assessment of titanium metallization thin film deposited on alumina substrate: Microstructure and nano-indentation.
Clicks: 448
ID: 50375
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
448 views
49 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #3 of 41 articles by views in Journal of the mechanical behavior of biomedical materials
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Surface titanium (Ti) metallization was conducted on alumina (AlO) through chemical vapor deposition (CVD) method derived from non-contact pack cementation. The effects of different deposition temperature (1000 °C, 1050 °C, and 1100 °C) were examined in this scenario. The morphology, phase composition, and interfacial defects of the resulting films were systematically investigated through scanning electron microscopy, energy dispersive spectrometry, and X-ray diffraction. The nanomechanical characterization of the proposed thin films was evaluated by conducting nano-indentation tests at different depths. The results revealed that uniform Ti films were coated on the AlO substrate. During coating, the atoms on the matrix surface were driven to form different structure due to different deposition temperature, leading to disparate morphologies of the surface and the interface, which consequently influenced the binding force between the film and the substrate. Moreover, the nanomechanical properties were found to be related to the internal and interface structure. Decreased modulus and hardness were obtained for metallization films treated at 1050 °C, and plastic deformation was the main deformation pattern.
| Reference Key |
xing2018assessmentjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Xing, Xuegang;Wang, Hefeng;Xiao, Gesheng;Yang, Shangyu;Shu, Xuefeng; |
| Journal | Journal of the mechanical behavior of biomedical materials |
| Year | 2018 |
| DOI |
S1751-6161(18)30053-5
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.