A modified method for a customized harvest of fibula free flap in maxillofacial reconstruction.
Clicks: 348
ID: 49702
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
65.0
/100
348 views
229 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #2 of 4 articles by views in journal of stomatology, oral and maxillofacial surgery
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Mandibular reconstruction using computer-aided design/computer-aided manufacturing cutting guides is currently a common procedure. However, inaccurate positioning of the cutting guide onto the fibular bone may result in osteosynthesis difficulties or imprecision in the reconstruction. A novel way to improve the stability of the cutting guides may be to add pillars in order for them to be suspended from the fibula, avoiding soft tissues interactions. We present the case of a 39-year-old male who needed mandibular reconstruction after a self-inflicted ballistic injury. We designed a customized cutting guide which included a set of 8 pillars allowing a suspension of the cutting guide 8 millimeters above the bone level. The pillars were perpendicular to one another, and allowed the operator to screw the cutting guide to the bone. The orthogonal position of the pillars enabled real stability during the osteotomies. In the operator experience, the length of the pillars was too important, and led to incomplete osteotomies, and the whole device was too bulky. However, with adaptations in the size of the pillars and the size of the whole device, this solution could be useful in cutting guide design to avoid impairments due to the soft tissues surrounding the fibula.
| Reference Key |
druelle2019ajournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Druelle, C;Schlund, M;Lutz, J-C;Constant, M;Raoul, G;Nicot, R; |
| Journal | journal of stomatology, oral and maxillofacial surgery |
| Year | 2019 |
| DOI |
S2468-7855(19)30201-0
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.