Theoretical study of heat pump system using CO2/dimethylether as refrigerant
Clicks: 463
ID: 49075
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
82.8
/100
463 views
315 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #2 of 14 articles by views in thermal science
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Nowadays, HCFC22 is widely used in heat pump systems in China, which should
be phased out in the future. Thus, eco-friendly mixture CO2/dimethylether
is proposed to replace HCFC22. Compared with pure CO2 and pure
dimethylether, the mixture can reduce the heat rejection pressure, and
suppress the flammability and explosivity of pure dimethylether. According
to the Chinese National Standards on heat pump water heater and space
heating system, performances of the subcritical heat pump system are
discussed and compared with those of the HCFC22 system. It can be concluded
that CO2 /dimethylether mixture works efficiently as a refrigerant for heat
pumps with a large heat-sink temperature rise. When mass fraction of
dimethylether is increased, the heat rejection pressure is reduced. Under
the nominal working condition, there is an optimal mixture mass fraction of
28/72 of CO2/dimethylether for water heater application under conventional
condensation pressure, 3/97 for space heating application. For water heater
application, both the heating coefficient of performance and volumetric
heating capacity increase by 17.90% and 2.74%, respectively, compared with
those of HCFC22 systems. For space heating application, the heating
coefficient of performance increases by 8.44% while volumetric heating
capacity decreases by 34.76%, compared with those of HCFC22 systems. As the
superheat degree increases, both the heating coefficient of performance and
volumetric heating capacity tend to decrease.
| Reference Key |
xiaowei2013theoreticalthermal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Xiao-Wei, Fan;Xian-Ping, Zhang;Fu-Jun, Ju;Fang, Wang; |
| Journal | thermal science |
| Year | 2013 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments