Validity of accelerometry in step detection and gait speed measurement in orthogeriatric patients.

Clicks: 277
ID: 48729
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1,051 of 2,056 articles by views in PloS one

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 2,056 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Mobile accelerometry is a powerful and promising option to capture long-term changes in gait in both clinical and real-world scenarios. Increasingly, gait parameters have demonstrated their value as clinical outcome parameters, but validation of these parameters in elderly patients is still limited.The aim of this study was to implement a validation framework appropriate for elderly patients and representative of real-world settings, and to use this framework to test and improve algorithms for mobile accelerometry data in an orthogeriatric population.Twenty elderly subjects wearing a 3D-accelerometer completed a parcours imitating a real-world scenario. High-definition video and mobile reference speed capture served to validate different algorithms.Particularly at slow gait speeds, relevant improvements in accuracy have been achieved. Compared to the reference the deviation was less than 1% in step detection and less than 0.05 m/s in gait speed measurements, even for slow walking subjects (< 0.8 m/s).With the described setup, algorithms for step and gait speed detection have successfully been validated in an elderly population and demonstrated to have improved performance versus previously published algorithms. These results are promising that long-term and/or real-world measurements are possible with an acceptable accuracy even in elderly frail patients with slow gait speeds.
Reference Key
keppler2019validityplos Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Keppler, Alexander M;Nuritidinow, Timur;Mueller, Arne;Hoefling, Holger;Schieker, Matthias;Clay, Ieuan;Böcker, Wolfgang;Fürmetz, Julian;
Journal PloS one
Year 2019
DOI
10.1371/journal.pone.0221732
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.