Green ultrasound assisted magnetic nanofluid-based liquid phase microextraction coupled with gas chromatography-mass spectrometry for determination of permethrin, deltamethrin, and cypermethrin residues.

Clicks: 349
ID: 48429
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #27 of 75 articles by views in Mikrochimica acta

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Ultrasound-assisted magnetic nanofluid-based liquid-phase microextraction was coupled to GC-MS in a method for simultaneous determination of the pyrethroid insecticides permethrin, deltamethrin, and cypermethrin. A highly efficient extraction solvent called "magnetic nanofluid (MNF)" is introduced for preconcentration of pyrethroids. The MNF consists of magnetic multiwalled carbon nanotubes (MMWCNTs) and deep eutectic solvent. Following microextraction, the MNF was detached by an external magnet from the medium without the need for centrifugation. 2-Pyridinecarboxamide, choline chloride, and anhydrous ferric chloride were used for the synthesis of the deep eutectic solvent. The effects of pH value, volume of MNF, sonication time, sample volume, and ionic strength, type and amount of back extraction solvent were investigated. Under optimum conditions of MNF volume of 50 μL, time of 5 min, 100 μL acetone as back extraction solvent, NaCl concentration of 1 mol.L and sample volume of 30 mL, the detection limits are 2.8, 2.7 and 2.0 ng·mL for permethrin, deltamethrin and cypermethrin, respectively. The linear response ranges are between 0.01 and 250 ng·mL, and relative standard deviations (for n = 7) are 3.5, 3.2 and 2.8%. The method was successfully applied to the determination of trace levels of permethrin, deltamethrin and cypermethrin in (spiked) milk samples. Graphical abstract Schematic representation of ultrasound assisted magnetic nanofluid-based liquid phase microextraction separation/preconcentration of permethrin, deltametrin, and cypermethrin residues in milk using GC-MS.
Reference Key
shirani2019greenmikrochimica Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Shirani, Mahboube;Akbari-Adergani, Behrouz;Jazi, Masoud Boroumand;Akbari, Ali;
Journal Mikrochimica acta
Year 2019
DOI
10.1007/s00604-019-3763-4
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.