Stretchable, Patch-Type Calorie-Expenditure Measurement Device Based on Pop-Up Shaped Nanoscale Crack-Based Sensor.

Clicks: 194
ID: 47967
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #15 of 18 articles by views in Advanced healthcare materials

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Demands for precise health information tracking techniques are increasing, especially for daily dietry requirements to prevent obesity, diabetes, etc. Many commercially available sensors that detect dynamic motions of the body lack accuracy, while novel strain sensors at the research level mostly lack the capability to analyze measurements in real life conditions. Here, a stretchable, patch-type calorie expenditure measurement system is demonstrated that integrates an ultrasensitive crack-based strain sensor and Bluetooth-enabled wireless communication circuit to offer both accurate measurements and practical diagnosis of motion. The crack-based strain gauge transformed into a pop-up-shaped structure provides reliable measurements and broad range of strain (≈100%). Combined with the stretchable analysis circuit, the skin attachable tool translates variation of the knee flexion angle into calorie expenditure amount, using relative resistance change (R/R ) data from the flexible sensor. As signals from the knee joint angular movement translates velocity and walking/running behavior, the total amount of calorie expenditure is accurately analyzed. Finally, theoretical, experimental, and simulation analysis of signal stability, dynamic noises, and calorie expenditure calculation obtained from the device during exercise are demonstrated. For further applications, the devices are expected to be used in broader range of dynamic motion of the body for diagnosis of abnormalities and for rehabilitation.
Reference Key
kwon2019stretchableadvanced Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kwon, Ki Yoon;Shin, Yiel Jae;Shin, Joo Hwan;Jeong, Chanho;Jung, Yei Hwan;Park, Byeonghak;Kim, Tae-Il;
Journal Advanced healthcare materials
Year 2019
DOI
10.1002/adhm.201801593
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.