Ultrasensitive electrochemical sensor for prostate specific antigen detection with a phosphorene platform and magnetic covalent organic framework signal amplifier.
Clicks: 292
ID: 47565
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
292 views
59 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #39 of 85 articles by views in Biosensors & bioelectronics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Magnetic covalent organic frameworks (COFs) are useful mesoporous materials for the enrichment and separation of analytes, and are utilized in the pretreatment of samples. However, the use of magnetic COFs in electrochemical immunosensors has rarely reported. Herein, a novel electrochemical assay for the determination of prostate specific antigen (PSA) was developed using black phosphorene (BPene) as a platform and magnetic COFs for signal amplification. BPene was prepared via water-phase exfoliation. BPene nanocomposite (Au@BPene) was prepared by depositing Au nanoparticles (Au NPs) onto BPene. This nanocomposite was utilized as an immunsensing platform to bind primary antibodies and improve electron transfer. Subsequently, an Au NP-loaded magnetic COF was used to immobilize the secondary antibodies and abundant electronic signals of methylene blue (MB). The fabricated sensor exhibited linearity ranging from 0.0001 ng mL to 10 ng mL with the detection limit of 30 fg mL. The sensor could determine the PSA in a real sample with excellent specificity, good stability, and desirable reproducibility. The effective signal amplification of the proposed sensor is attributed to the good electron transfer of Au@BPene, excellent enrichment capacity of signal molecules (MB) of the COF, and efficient catalytic activity of FeO. This work not only provides an effective electrochemical assay to detect PSA in real sample, but also broadens the utilization scope of magnetic COFs in immunosensing.
| Reference Key |
liang2019ultrasensitivebiosensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Liang, Huan;Xu, Hanbin;Zhao, Yuting;Zheng, Jing;Zhao, Hui;Li, Guoliang;Li, Can-Peng; |
| Journal | Biosensors & bioelectronics |
| Year | 2019 |
| DOI |
S0956-5663(19)30770-5
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.