[Application of flow cytometry to the evaluation of semen quality].
Clicks: 367
ID: 47410
2006
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
64.9
/100
367 views
237 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #2 of 6 articles by views in zhonghua nan ke xue = national journal of andrology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To evaluate the role of flow cytometry in semen assessment.Semen samples from 104 infertile male patients (as the case group) and 10 fertilized donors (as the control group) were analyzed for the volume of ejaculate and sperm concentration, motility and atypical morphology by computer-assisted semen analysis (CASA), the viability, chromatin structure and mitochondrial membrane potential (MMP) of the sperm stained by SYBR-14/PI, AO and JC-1 respectively, and assessed with flow cytometry. The results were analyzed through SAS software.U tests indicated that the semen from the infertile patients had not only lower concentration (U = 2.51, P = 0.0143), lower motility (U = 3.44, P = 0.001) and higher rate of atypical morphology (U = -5.88, P < 0.0001), but also lower viability (U = 4.72, P < 0.0001), MMP (U = -2.53, P = 0.0309), and chromatin integrity (alpha t: U = -3.82, P = 0.0003; SD alpha t: U = -3.98, P = 0.0001; COMP alpha t: U = -3.57, P = 0.0005). The multiple stepwise regression analysis revealed that sperm motility was positively correlated with sperm membrane integrity (t = 1.66, P = 0.1016), sperm MMP (t = 3.33, P = 0.0014) and sperm acrosome integrity (t = 3.24, P = 0.0019), while sperm MMP was negatively correlated with the rates of sperm neck and tail defects (t = -3.44, P = 0.001).Flow cytometry plays a significant role in the evaluation of the quality of human sperm, and can be adopted as a useful tool in the diagnosis and treatment of male infertility.
| Reference Key |
hua2006applicationzhonghua
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Hua, Yong;Qian, Xian-ming;Chen, Bing-guan;Yang, Jian-hua;Wu, Xiao-yun;Ma, Liang;Chen, Cui-ling; |
| Journal | zhonghua nan ke xue = national journal of andrology |
| Year | 2006 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.