Clinical performance and material properties of single-implant overdenture attachment systems.
Clicks: 313
ID: 46570
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Star Article
63.4
/100
306 views
251 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
The aim of this study was to evaluate the mechanical properties of different attachment systems used for mandibular single-implant overdentures and to compare their wear/deformation features with clinical performance in patients after 1 year.Three attachment systems were evaluated: large 5.9-mm titanium nitride-coated ball attachments with plastic matrices, standard 2.25-mm uncoated titanium alloy ball attachments with Dalla Bona-type gold alloy matrices, and Locator attachments of titanium nitride-coated patrices and nylon matrices. The hardness and elastic modulus of the systems were determined using the nanoindentation technique. Twelve attachments from each system were used in 36 edentulous patients to support mandibular single-implant overdentures. After 1 year, 5 samples from each system were retrieved and evaluated for wear changes under a scanning electron microscope.The titanium nitride-coated patrices, regardless of system, appeared unchanged and did not require any maintenance. Extensive wear was evident in the uncoated titanium alloy patrices and Dalla Bona-type gold alloy matrices, resulting in high maintenance (15 activations). Minimal wear was observed in the plastic matrices with minimal maintenance (2 replacements). The Locator nylon matrices showed extensive deformation and deterioration with a substantial need for maintenance (16 replacements). The performance of the patrices was related to hardness, while that of the matrices was related to the creep response.Large ball attachment systems of titanium nitride-coated patrices and plastic matrices reflect favorable wear behavior and clinical performance. These attachments are recommended for patients receiving mandibular single-implant overdentures.
| Reference Key |
alsabeehaclinicalthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Alsabeeha, Nabeel H M;Swain, Michael V;Payne, Alan G T; |
| Journal | the international journal of prosthodontics |
| Year | Year not found |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.