Validated spectrophotometric and chromatographic methods for simultaneous determination of ketorolac tromethamine and phenylephrine hydrochloride.
Clicks: 286
ID: 45982
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
286 views
20 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #16 of 77 articles by views in annales pharmaceutiques francaises
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This work describes five simple and reliable spectrophotometric and chromatographic methods for analysis of the binary mixture of ketorolac tromethamine (KTR) and phenylephrine hydrochloride (PHE). Method I is based on the use of conventional Amax and derivative spectrophotometry with the zero-crossing technique where KTR was determined using its Amax and (1)D amplitudes at 323 and 341nm respectively, while PHE was determined by measuring the (1)D amplitudes at 248.5nm. Method II involves the application of the ratio spectra derivative spectrophotometry. For KTR, 12μg/mL PHE was used as a divisor and the (1)DD amplitudes at 265nm were plotted against KTR concentrations; while - by using 4μg/mL KTR as divisor - the (1)DD amplitudes at 243.5nm were found proportional to PHE concentrations. Method III depends on ratio-difference measurement where the peak to trough amplitudes between 260 and 284nm were measured and correlated to KTR concentration. Similarly, the peak to trough amplitudes between 235 and 260nm in the PHE ratio spectra were recorded. For method IV, the two compounds were separated using Merck HPTLC sheets of silica gel 60 F254 and a mobile phase composed of chloroform/methanol/ammonia (70:30:2, by volume) followed by densitometric measurement of KTR and PHE spots at 320 and 278nm respectively. Method V depends on HPLC-DAD. Effective chromatographic separation was achieved using Zorbax eclipse plus C8 column (4.6×250mm, 5μm) with a mobile phase consisting of 0.05M o-phosphoric acid and acetonitrile (50:50, by volume) at a flow rate 1mL/min and detection at 313 and 274nm for KTR and PHE respectively. Analytical performance of the developed methods was statistically validated according to the ICH guidelines with respect to linearity, ranges, precision, accuracy, detection and quantification limits. The validated spectrophotometric and chromatographic methods were successfully applied to the simultaneous analysis of KTR and PHE in synthetic mixtures of different proportions and laboratory-made ophthalmic solution.
| Reference Key |
belal2016validatedannales
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Belal, T S;El-Kafrawy, D S;Mahrous, M S;Abdel-Khalek, M M;Abo-Gharam, A H; |
| Journal | annales pharmaceutiques francaises |
| Year | 2016 |
| DOI |
10.1016/j.pharma.2015.12.006
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.