The effect of using different coordinate systems on in-vivo hip angles can be estimated from computed tomography images.
Clicks: 307
ID: 45889
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
307 views
37 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #11 of 22 articles by views in journal of biomechanics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Measurements of hip kinematics inherently depend on the coordinate system in which they are derived, yet the effect of the coordinate system definition on calculations of hip angles is not well-understood. Herein, hip angles calculated during dynamic activities were compared using coordinate systems described in the literature. In-vivo kinematic data of 24 participants (13 males) were analyzed during gait and the anterior impingement test using dual fluoroscopy and model-based tracking. Two coordinate systems for the pelvis (anterior pelvic plane, International Society of Biomechanics [ISB]) and three coordinate systems for the femur (table top plane with two definitions of the superior-inferior axis, ISB) were evaluated. Bony landmarks visible on computed tomography (CT) images were identified to establish each coordinate system and used as the basis to calculate differences in hip angles between coordinate system pairs. In the analysis during gait, the maximum differences derived from various coordinate system definitions were 6.7° ± 5.5° for flexion, 7.7° ± 2.1° for rotation, and 5.5° ± 0.7° for adduction. For the anterior impingement test, the differences were 8.1° ± 5.9°, 7.1° ± 1.2°, and 5.3° ± 0.7°, respectively. Landmark-based analysis using CT images could estimate these dynamic differences with errors less than 1.0°. Our results indicate that hip angles can be accurately transformed to angles calculated in different coordinate systems by accounting for the inherent bony anatomy. This information may aid in the interpretation of results across biomechanical studies of the hip.
| Reference Key |
uemura2019thejournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Uemura, Keisuke;Atkins, Penny R;Anderson, Andrew E; |
| Journal | journal of biomechanics |
| Year | 2019 |
| DOI |
S0021-9290(19)30530-5
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.