Direct comparison of supervised and semi-supervised retraining approaches for co-adaptive BCIs.

Clicks: 257
ID: 45849
2019
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
For Brain-Computer interfaces (BCIs), system calibration is a lengthy but necessary process for successful operation. Co-adaptive BCIs aim to shorten training and imply positive motivation to users by presenting feedback already at early stages: After just 5 min of gathering calibration data, the systems are able to provide feedback and engage users in a mutual learning process. In this work, we investigate whether the retraining stage of co-adaptive BCIs can be adapted to a semi-supervised concept, where only a small amount of labeled data is available and all additional data needs to be labeled by the BCI itself. The aim of the current work was to evaluate whether a semi-supervised co-adaptive BCI could successfully compete with a supervised co-adaptive BCI model. In a supporting two-class (190 trials per condition) BCI study based on motor imagery tasks, we evaluated both approaches in two separate groups of 10 participants online, while we simulated the other approach in each group offline. Our results indicate that despite the lack of true labeled data, the semi-supervised driven BCI did not perform significantly worse (p > 0.05) than the supervised counterpart. We believe that these findings contribute to developing BCIs for long-term use, where continuous adaptation becomes imperative for maintaining meaningful BCI performance. Graphical abstract In this work, we investigate whether the retraining stage of a co-adaptive BCI can be adapted to a semi-supervised concept, where only a small amount of labeled data is available and all additional data needs to be labeled by the BCI itself. In two groups of 10 persons, we evaluate a supervised as well as a semi-supervised approach. Our results indicate that despite the lack of true labeled data, the semi-supervised driven BCI did not perform significantly worse (p > 0.05) than the supervised counterpart.
Reference Key
schwarz2019directmedical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Schwarz, Andreas;Brandstetter, Julia;Pereira, Joana;Müller-Putz, Gernot R;
Journal Medical & biological engineering & computing
Year 2019
DOI
10.1007/s11517-019-02047-1
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.