A Novel Mass-Producible Capacitive Sensor with Fully Symmetric 3D Structure and Microfluidics for Cells Detection
Clicks: 508
ID: 45476
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
79.9
/100
508 views
318 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #25 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Affinity biosensors of interdigitated electrodes have been widely used in cell detection. This research presents a mass-producible and disposable three-dimensional (3D) structure capacitive sensor based on the integrated circuit package lead frames for cell concentration detection. The fully symmetric 3D interdigital electrode structure makes the sensor more homogeneous and sensitive. (3-Aminopropyl) triethoxysilane (APTES) and glutaraldehyde are immobilized onto gold-plated electrodes. By overlaying the microfluidic channels on top, the volume of the solution is kept constant to obtain repeatable measured capacitance values. Moreover, using the upgraded reading and writing functions and circular measurement of the E4980A Data Transfer Program, an automatic multigroup test system is developed. It is shown that the cell concentration and capacitance are inversely correlated, and the cell concentration range of 103–106 CFU∙mL−1 is achieved. In addition, the rate of capacitance change matches that of state-of-the-art biosensors reported. A program is developed to find the optimal voltage and frequency for linear fitting between the capacitance change and cell concentration. Future work will employ machine learning-based data analysis to drug resistance sensitivity test of cell lines and cell survival status.
| Reference Key |
zuo2019asensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zuo, Zhaorui;Wang, Kun;Gao, Libin;Ho, Vincent;Mao, Hongju;Qian, Dahong; |
| Journal | sensors |
| Year | 2019 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.