A Novel Mass-Producible Capacitive Sensor with Fully Symmetric 3D Structure and Microfluidics for Cells Detection

Clicks: 508
ID: 45476
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #25 of 1,694 articles by views in sensors

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Affinity biosensors of interdigitated electrodes have been widely used in cell detection. This research presents a mass-producible and disposable three-dimensional (3D) structure capacitive sensor based on the integrated circuit package lead frames for cell concentration detection. The fully symmetric 3D interdigital electrode structure makes the sensor more homogeneous and sensitive. (3-Aminopropyl) triethoxysilane (APTES) and glutaraldehyde are immobilized onto gold-plated electrodes. By overlaying the microfluidic channels on top, the volume of the solution is kept constant to obtain repeatable measured capacitance values. Moreover, using the upgraded reading and writing functions and circular measurement of the E4980A Data Transfer Program, an automatic multigroup test system is developed. It is shown that the cell concentration and capacitance are inversely correlated, and the cell concentration range of 103–106 CFU∙mL−1 is achieved. In addition, the rate of capacitance change matches that of state-of-the-art biosensors reported. A program is developed to find the optimal voltage and frequency for linear fitting between the capacitance change and cell concentration. Future work will employ machine learning-based data analysis to drug resistance sensitivity test of cell lines and cell survival status.
Reference Key
zuo2019asensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Zuo, Zhaorui;Wang, Kun;Gao, Libin;Ho, Vincent;Mao, Hongju;Qian, Dahong;
Journal sensors
Year 2019
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.