Analysis of parameters affecting blood oxygen saturation and modeling of fuzzy logic system for inspired oxygen prediction.
Clicks: 441
ID: 4492
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
73.0
/100
441 views
314 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #4 of 70 articles by views in computer methods and programs in biomedicine
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Fraction of Inspired Oxygen is one of the arbitrary set ventilator parameters which has critical influence on the concentration of blood oxygen. Normally mechanical ventilators providing respiratory assistance are tuned manually to supply required inspired oxygen to keep the oxygen saturation at the desired level. Maintaining oxygen saturation in the desired limit is so vital since excess supply of inspired oxygen leads to hypercapnia and respiratory acidosis which lead to increased risk in cell damage and death. On the other side a sudden drop in oxygen saturation will lead to severe cardiac arrest and seizure. Hence intelligent real time control of blood oxygen level saturation is highly significant for patients in intensive care units.This paper gives statistical pair wise analysis for finding out deeply correlated physiological parameters from clinical data for fixing fuzzy variables. An advisory fuzzy controller using Mamdani model is developed with R programming to predict FiO which is to be delivered from the ventilator to maintain SaO with in required levels.Fuzzy variables for the fuzzy model is fixed using 75% of the clinical data collected. Remaining 25% of the data is used for checking the system. Compared the predictive output of the system with physicians' decisions and found to be accurate with less than five percentage error.Based on the comparison the system is proved to be effective and can be used as assist mode for physicians for effective decision making.
| Reference Key |
radhakrishnan2019analysiscomputer
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Radhakrishnan, Sita;Nair, Suresh G;Isaac, Johney; |
| Journal | computer methods and programs in biomedicine |
| Year | 2019 |
| DOI |
S0169-2607(18)31783-8
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.