Sensing of DNA by graphene-on-silicon FET structures at DC and 101 GHz
Clicks: 340
ID: 44500
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
72.2
/100
340 views
234 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #2 of 6 articles by views in sensing and bio-sensing research
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A graphene–silicon field-effect transistor (GFET) structure is demonstrated as a detector of single-stranded 13-mer DNA simultaneously at DC and 101 GHz at three different molarities: 0.01, 1.0 and 100 nM. The mechanism for detection at DC is the DNA-induced change in lateral sheet conductance, whereas at 101 GHz it is the change in RF sheet conductance and the resulting effect on the perpendicular beam transmittance through the GFET acting as an optical etalon. For example, after application and drying of the DNA on a GFET film biased to a DC sheet conductance of 2.22 mS, the 1.0 nM solution is found to reduce this by 1.24 mS with a post-detection signal-to-noise ratio of 43 dB, and to increase the transmitted 101-GHz signal from 0.828 to 0.907 mV (arbitrary units) with a post-detection signal-to-noise ratio of 36 dB. The increase in transmittance is consistent with a drop of the 101-GHz sheet conductance, but not as much drop as the DC value. Excellent sensitivity is also achieved with the 0.01-nm solution, yielding a DC SNR of 41 dB and a 101-GHz SNR of 23 dB. Keywords: Graphene, DNA, THz, DC, Detection
| Reference Key |
brown2015sensingsensing
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Brown, E.R.;Zhang, W.-D.;Viveros, L.;Neff, D.;Green, N.S.;Norton, M.L.;Pham, P.H.Q.;Burke, P.J.; |
| Journal | sensing and bio-sensing research |
| Year | 2015 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.