Microvesicle detection by a reduced graphene oxide field-effect transistor biosensor based on a membrane biotinylation strategy.

Clicks: 254
ID: 44455
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #37 of 50 articles by views in The Analyst

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Unlike other extracellular vesicle (EV) subtypes such as exosomes, the lack of well-defined universal markers on the surface of microvesicles (MVs) has led to difficulty in the detection of the entire MV population. To design a universal MV detection method, we reported highly sensitive electrical detection of MVs using a reduced graphene oxide (RGO)-based field-effect transistor (FET) biosensor by the introduction of a membrane biotinylation strategy in this work. Biotinylated MVs (B-MVs) were obtained by supplying the culture medium with 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-[biotinyl(polyethylene glycol)-2000] (DSPE-PEG-biotin) while cultivating the cells. Excellent biotinylation efficiency of MVs (92.6%) was then realized. A streptavidin (SA) probe was subsequently modified onto the channel surface of the as-fabricated RGO-based FET device, which was capable of specifically recognizing B-MVs due to the high affinity between SA and biotin in a 1 : 4 recognition format. The results showed that the RGO-based FET biosensor could detect B-MVs in a wide range from 105 particles per mL to 109 particles per mL with a low detection limit down to 20 particles per μL, which was the lowest value compared with other previously reported results. This platform also allowed distinguishing B-MVs from other unbiotinylated EV types such as MVs and exosomes, exhibiting excellent specificity. Moreover, this FET biosensor demonstrated the capability of detecting B-MVs derived from different cell lines including cancer cells and normal cells, indicating its versatility and potential applications in the biomedical field.
Reference Key
wu2019microvesiclethe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal The Analyst
Year 2019
DOI
10.1039/c9an01332f
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.