Microfluidic impedance cytometry device with N-shaped electrodes for lateral position measurement of single cells/particles.
Clicks: 428
ID: 43779
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
66.9
/100
428 views
309 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #4 of 18 articles by views in lab on a chip
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Tracking the lateral position of single cells and particles plays an important role in evaluating the efficiency of microfluidic cell focusing, separation and sorting. In this work, we present an N-shaped electrode-based microfluidic impedance cytometry device for the measurement of the lateral position of single cells and particles in continuous flows. Specifically, a simple analytical expression for determining the particle lateral position is derived from the measured electrical signal and geometry relationship among the positions of the flowing particles, electrodes and microchannel. This microfluidic system is experimentally validated by measuring the lateral positions of 5, 7 and 10 μm diameter beads and human red blood cells (RBCs) flowing in a 200 μm wide channel at varying flow rates up to 59.3 μl min-1. Statistical analyses show a good correlation (R2 = 0.99) and agreement (Bland-Altman analysis) between our results and those obtained by a microscopy imaging method. The resolution of our system reflected by the root-mean-square deviation (RMSD) is 10.3 μm (5.15% of the channel width) for 5 and 10 μm beads, and 11.4 μm (5.7% of the channel width) for RBCs at a flow rate of 42.4 μl min-1. Compared to the existing impedance-based methods for measuring the particle lateral position, we achieve the highest resolution, highest flow rate and smallest measured particle size (3.6 μm beads). The experimental results of the mixture with 5 and 10 μm beads demonstrate that our device does not merely measure the lateral position of single particles or cells, but also can characterize their physical properties (e.g., size) simultaneously. Furthermore, we demonstrate the position monitoring of sheath flow-induced particle focusing, which is in quantitative agreement with the results by imaging quantification. With the advantages of rapid and accurate processing of electrical signal and high throughput of the impedance flow cytometry, this novel N-shaped electrode-based system can be easily integrated with other microfluidic platforms as a downstream approach for the real-time measurement of the lateral position and physical properties of single cells and particles.
| Reference Key |
yang2019microfluidiclab
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Yang, Dahou;Ai, Ye; |
| Journal | lab on a chip |
| Year | 2019 |
| DOI |
10.1039/c9lc00819e
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.