Performance and Short-term Outcomes of Three Different TAVR Devices in Patients with Aortic Stenosis: A Single-center Experience.
Clicks: 374
ID: 43725
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
374 views
41 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #3 of 14 articles by views in journal of the chinese medical association : jcma
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Data on whether different transcatheter aortic valve replacement (TAVR) devices and delivery approaches can achieve equally favorable outcomes when performed by a single heart team are scarce. We sought to compare the performance and short-term outcomes of three different TAVR devices - self-expanding Medtronic CoreValve (MCV), mechanically expanded Lotus valve (Boston Scientific), and balloon-expandable Edwards SAPIEN XT (SXT) - for the treatment of severe aortic stenosis (AS) in a single large-volume center in Taiwan.We retrospectively reviewed consecutive patients who underwent TAVR for the treatment of severe AS. Clinical outcomes were reported following Valve Academic Research Consortium 2 (VARC-2) criteria. The composite primary endpoint was combined all-cause mortality, myocardial infarction (MI), or disabling stroke within 180 days.A total of 231 patients (MCV n=112, Lotus n=18, and SXT n=101) were included. The device and procedural success rates were similar among all three TAVR devices. At 30 days, there was no significant difference in all-cause mortality, cardiovascular mortality, periprocedural MI, stroke, major vascular complications, life-threatening bleeding, acute kidney injury (AKI) stage 2/3, or VARC-2 composite early safety endpoints. There was no difference among groups in rate of primary endpoint within 180 days. Lack of procedural success, presence of acute coronary occlusion during TAVR, and presence of AKI stage 3 after TAVR were independent predictors of adverse outcomes.TAVR using MCV, Lotus, or SXT was associated with similar 30-day and 180-day clinical outcomes. The presence of periprocedural complications were main determinants of short-term adverse outcomes.
| Reference Key |
tzeng2019performancejournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Tzeng, Yun-Hsuan;Lee, Yung-Tsai;Tsao, Tien-Ping;Lee, Kuo-Chen;Huang, Kuan-Chih;Hsiung, Ming-Chon;Wei, Jeng;Yin, Wei-Hsian; |
| Journal | journal of the chinese medical association : jcma |
| Year | 2019 |
| DOI |
10.1097/JCMA.0000000000000187
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.