Pulmonary Valve Function Late after Ross procedure in 443 adult patients.
Clicks: 276
ID: 43721
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
276 views
38 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #14 of 23 articles by views in the annals of thoracic surgery
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Limited data exists on long-term pulmonary valve function after the Ross procedure. This study sought to determine the long-term function of the pulmonary valve in 443 consecutive adult patients who underwent a Ross procedure.All 443 patients who underwent a Ross procedure between November 1992 and March 2018 were reviewed retrospectively. All underwent pulmonary valve replacement using a cryopreserved pulmonary allograft. Freedom from the study's outcomes were calculated using Kaplan Meier survival. Risk factors for valve failure were analyzed using Cox regression.Mean age at time of operation was 39 years (range 15-66 years). There was 1 (0.2%, 1/443) operative mortality. Nine patients required reintervention on the pulmonary allograft at a mean 6.1 years (range 1-12 years) after Ross procedure. Patients required pulmonary allograft reintervention for infective endocarditis (n=4), severe pulmonary stenosis (n=4) or severe pulmonary regurgitation (PR) (n=1). Freedom from pulmonary allograft reintervention was 98.9% (95%CI 97.1-99.6), 97.7% (95%CI 95.1-98.9), 96.6% (95%CI 93.3-98.3) and 96.6% (95%CI 93.3-98.3) at 5, 10, 15 and 20 years (Figure 1). Freedom from pulmonary allograft dysfunction (at least moderate PR and/or mean systolic gradient ≥ 25mmHg and/or reintervention) was 94.5% (95%CI 91.6-96.4), 88.1% (95%CI 83.6-91.4), 84.9% (95%CI 79.6-88.9) and 78.3% (95%CI 69.5-84.9) at 5, 10, 15 and 20 years. No risk factors were identified to influence pulmonary valve durability.The pulmonary valve allograft gives excellent long-term function when used in adults undergoing the Ross procedure. Reintervention on the pulmonary valve is rare and significant pulmonary allograft dysfunction is uncommon.
| Reference Key |
fricke2019pulmonarythe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Fricke, Tyson A;Skillington, Peter D;Shi, William;Buratto, Edward;Wynne, Rochelle;Larobina, Marco;Grigg, Leeanne; |
| Journal | the annals of thoracic surgery |
| Year | 2019 |
| DOI |
S0003-4975(19)31349-9
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.