Performance improvement of water-cooled screw chiller under part load operation conditions by the paralleling throttle mechanism
Clicks: 472
ID: 43004
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
84.6
/100
472 views
322 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #1 of 14 articles by views in thermal science
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Currently, water-cooled screw chiller is widely applied in commercial and industrial buildings, and the energy consumption of water chiller even could cover 70% of air-conditioning energy consumption in the most adverse operating conditions. Moreover, a number of chillers are running at a low rate under part-load state. In order to reduce the energy consumption of water-cooled screw chillers under part-load state, the paper presents the paralleling throttle mechanism. Through experimental study, under part-load state, it can be found that the by-pass tube diameter Ø16 has the most positive effect on the performance of water-cooled screw chiller in four by-pass tube diameters. The oblique access mode is better than the vertical access mode, while the spiral access mode has little influence on the chiller performance. Because of paralleling throttle using, the exergetic loss of the evaporator and chiller is able to be reduced by 3.4%-15.5% and 0-6.7%, respectively. Meanwhile, the coefficient of performance of chiller can be enhanced by 0.2%-1.6%, and discharge temperature can be reduced by 0.4-2.7°C. In addition, the economic and environmental benefits of the advanced water-cooled screw chiller are more evident than the conventional water-cooled screw chiller's.
| Reference Key |
long2018performancethermal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Long, Ni;Jijin, Wang;Dehu, Qv;Qiang, Cai;Yang, Yao; |
| Journal | thermal science |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.