Efficient Operation of Heat Source using High-temperature Chilled Water in an Advanced Office Building
Clicks: 357
ID: 43001
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
73.8
/100
357 views
224 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #14 of 271 articles by views in e3s web of conferences
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 271 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In recent years, energy conservation has become a major focus in the industrial sector. Many office buildings in Japan achieve energy savings by introducing highly efficient equipment and systems, such as high-temperature cooling water (14 °C), which increases heat source efficiency. However, such equipment requires adjustments to increase operational efficiency. In this case study, the efficiency of equipment using high-temperature cooling water was further improved through operation control optimization. The energy efficiency before and after the improvement was compared. The target building has chilled and hot water supplied to each floor from district heating and high-temperature chilled water supplied from cooling chillers on the rooftop. The energy consumption of two floors was evaluated: a subjective floor with equipment using high-temperature cooling water installed, and a common floor with a conventional system. After on-site verification, changes were made to the operation control of the cooling towers, condenser pumps, primary pumps, secondary pumps, and air handling units. As a result, the coefficient of performance of the water-cooled chiller and the whole system improved by 0.40 and 0.45, respectively. The flow rate of the air conditioning equipment using high-temperature cooling water decreased while maintaining an equivalent amount of heat extraction. In conclusion, the efficiency of the equipment was further improved by operation control optimization.
| Reference Key |
yuya2019efficiente3s
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Yuya, Suzuki;Misa, Imazu;Jun, Shinoda;Ryoya, Furukawa;Yumiko, Araki;Shin-ichi, Tanabe;Kenji, Fujino;Daisuke, Hatori;Nobuhiro, Hirasuga;Shun, Kato;Shiori, Sasahara;Hiroki, Iwata; |
| Journal | e3s web of conferences |
| Year | 2019 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.